Warning Icon
This product was discontinued on: June 30, 2015

For other alternatives, please contact us for more information.

0 Replacement products available

4110103 | 2312K CMRL 1//2" PLENUM TRUNK 2400

75 Ohm P3® 500 JCAP 1/2" Plemum Trunk and Distribution Cable, cream flame retardant PVDF jacket

Specifications
Finish making your selections or clear them to view relevant specifications.

Product Classification

Product Type Coaxial hardline cable
Product Brand P3®
Warranty One year

General Specifications

Cable Type 500 Series
Construction Type Swaged
Jacket Color Cream
Short Description P3 500 JCAP (2312K)

Dimensions

Cable Length 731.52 m | 2400 ft
Diameter Over Center Conductor, nominal 2.769 mm | 0.109 in
Diameter Over Dielectric, nominal 11.481 mm | 0.452 in
Diameter Over Jacket, nominal 13.31 mm | 0.524 in
Diameter Over Outer Conductor, nominal 12.7 mm | 0.5 in
Jacket Thickness, nominal 0.305 mm | 0.012 in
Outer Conductor Thickness, nominal 0.61 mm | 0.024 in

Electrical Specifications

Capacitance 52.493 pF/m | 16 pF/ft
Capacitance Tolerance ±1.0 pF/ft
Characteristic Impedance 75 ohm
Characteristic Impedance Tolerance ±2 ohm
dc Resistance Note Nominal values based on a standard condition of 20 °C (68 °F)
dc Resistance, Inner Conductor, nominal 4.659 ohms/km | 1.42 ohms/kft
dc Resistance, Loop, nominal 5.873 ohms/km | 1.79 ohms/kft
dc Resistance, Outer Conductor, nominal 1.214 ohms/km | 0.37 ohms/kft
Jacket Spark Test Voltage 1000 Vac
Nominal Velocity of Propagation (NVP) 86 %
Structural Return Loss 20 dB @ 450–1218 MHz | 24 dB @ 5–450 MHz

Attenuation

Frequency Attenuation (dB/100 m) Attenuation (dB/100 ft)
5.0 MHz 0.620 0.190
10.0 MHz 0.850 0.260
50.0 MHz 2.000 0.610
85.0 MHz 2.230 0.820
100.0 MHz 2.980 0.910
200.0 MHz 4.490 1.370
204.0 MHz 3.510 1.380
400.0 MHz 7.120 2.170
700.0 MHz 10.520 3.210
900.0 MHz 12.540 3.720
1000.0 MHz 13.650 4.160
1002.0 MHz 13.670 4.170
1218.0 MHz 15.910 4.850
1400.0 MHz 17.760 5.410
1500.0 MHz 18.760 5.720
1600.0 MHz 19.750 6.020
1700.0 MHz 20.740 6.320
1794.0 MHz 21.660 6.600
1800.0 MHz 21.720 6.620

Material Specifications

Center Conductor Material Copper-clad aluminum
Dielectric Material FFEP
Jacket Material Fire retardant PVDF
Outer Conductor Material Aluminum

Mechanical Specifications

Minimum Bend Radius, standard 203.2 mm | 8 in
Pulling Tension, maximum 136.078 kg | 300 lb

Environmental Specifications

Environmental Space Indoor | Plenum
Temperature Rating, UL 125 °C | 257 °F
Flame Test Listing CATVP | CMP | NEC Article 820

Packaging and Weights

Packaging Type Reel
Weight, gross 226.201 kg/km | 152 lb/kft

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system
ROHS Compliant
CHINA-ROHS Below maximum concentration value
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
UK-ROHS Compliant

Product Classification

Product Type Coaxial hardline cable
Product Brand P3®
Warranty One year

General Specifications

Cable Type 500 Series
Construction Type Swaged
Jacket Color Cream
Short Description P3 500 JCAP (2312K)

Dimensions

Cable Length 731.52 m | 2400 ft
Diameter Over Center Conductor, nominal 2.769 mm | 0.109 in
Diameter Over Dielectric, nominal 11.481 mm | 0.452 in
Diameter Over Jacket, nominal 13.31 mm | 0.524 in
Diameter Over Outer Conductor, nominal 12.7 mm | 0.5 in
Jacket Thickness, nominal 0.305 mm | 0.012 in
Outer Conductor Thickness, nominal 0.61 mm | 0.024 in

Electrical Specifications

Capacitance 52.493 pF/m | 16 pF/ft
Capacitance Tolerance ±1.0 pF/ft
Characteristic Impedance 75 ohm
Characteristic Impedance Tolerance ±2 ohm
dc Resistance Note Nominal values based on a standard condition of 20 °C (68 °F)
dc Resistance, Inner Conductor, nominal 4.659 ohms/km | 1.42 ohms/kft
dc Resistance, Loop, nominal 5.873 ohms/km | 1.79 ohms/kft
dc Resistance, Outer Conductor, nominal 1.214 ohms/km | 0.37 ohms/kft
Jacket Spark Test Voltage 1000 Vac
Nominal Velocity of Propagation (NVP) 86 %
Structural Return Loss 20 dB @ 450–1218 MHz | 24 dB @ 5–450 MHz

Attenuation

Frequency Attenuation (dB/100 m) Attenuation (dB/100 ft)
5.0 MHz 0.620 0.190
10.0 MHz 0.850 0.260
50.0 MHz 2.000 0.610
85.0 MHz 2.230 0.820
100.0 MHz 2.980 0.910
200.0 MHz 4.490 1.370
204.0 MHz 3.510 1.380
400.0 MHz 7.120 2.170
700.0 MHz 10.520 3.210
900.0 MHz 12.540 3.720
1000.0 MHz 13.650 4.160
1002.0 MHz 13.670 4.170
1218.0 MHz 15.910 4.850
1400.0 MHz 17.760 5.410
1500.0 MHz 18.760 5.720
1600.0 MHz 19.750 6.020
1700.0 MHz 20.740 6.320
1794.0 MHz 21.660 6.600
1800.0 MHz 21.720 6.620

Material Specifications

Center Conductor Material Copper-clad aluminum
Dielectric Material FFEP
Jacket Material Fire retardant PVDF
Outer Conductor Material Aluminum

Mechanical Specifications

Minimum Bend Radius, standard 203.2 mm | 8 in
Pulling Tension, maximum 136.078 kg | 300 lb

Environmental Specifications

Environmental Space Indoor | Plenum
Temperature Rating, UL 125 °C | 257 °F
Flame Test Listing CATVP | CMP | NEC Article 820

Packaging and Weights

Packaging Type Reel
Weight, gross 226.201 kg/km | 152 lb/kft

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system
ROHS Compliant
CHINA-ROHS Below maximum concentration value
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
UK-ROHS Compliant

Product Specification

Product Specification